YEM3D DC Plastic Shell Type Circuit Breaker are mainly used in DC systems

 

Rated current: 100~250A

 

Pole: 2P

Product Overview

 

YEM3D-250 DC circuit breakers are mainly used in DC systems with rated insulation voltage of 1600V,rated working voltage of DC 1500V and below,over load and short circuit protection foe power distribution and protection lines and power supply equipment in DC systems with rated current 250A and below.

Product Parameters

Product Choice

Name Details
Product category Moulded case circuit breaker
Design code 1
Product’s code DC=Plastic Shell Type Circuit Breaker
Breaking capacity 250
pole 2P
Release and part’s code 300 no part(Please see the release part NO.table)(P45)
Rated current 100A~250A
Operation type None=Manual direct operation P=Electric operation Z=Manual manipulation
Use NO. None=Power distribution type breaker 2=Protect motor

Precautions

Operating Conditions

 

1. Ambient temperature -5℃~+40℃。

 

2. Installation site of the elevation of not more than 2000m.

 

3. The relative humidity of the air at the installation site does not exceed 50%at a maximum temperature of +40℃and higher relative humidity at a lower temperature,for example 90% at 20℃.Special measures should be taken for condensation occasionally due to temperature changes.

 

4. Pollution level is 3.

 

5. Circuit breaker main circuit installation category Ⅲ,the remaining auxiliary circuits,cintril circuit installation category Ⅱ.

 

6. Circuit breakers foe electromagnetic environment A.

 

7. Circuit breakers should be installed in the absence of explosive and non-conductive dust,enough to corrode the metal and damage the insulation.

 

8. Circuit breakers should be installed in the absence of rain and snow invasion.

 

9. Storage conditions:ambient air temperature is -40℃~+70℃.

Hot Products

N series 16A-630A split type two working positions ATSE terminal blocks wiring automatic switches with 2p/3p/4p

N series 16A-630A split type two working positions ATSE terminal blocks wiring automatic switches with 2p/3p/4p

YE41F-1Z-C4-24 Slim interface relay Socket

YE41F-1Z-C4-24 Slim interface relay Socket

NA series 16A-630A integral type two working positions intelligent  ATSE with 2p/3p/4p

NA series 16A-630A integral type two working positions intelligent ATSE with 2p/3p/4p

YES1-NZ DC Automatic Transfer Switch

YES1-NZ DC Automatic Transfer Switch

YEM1E 32A-800A moulded case circuit breaker time delay function MCCB transient voltage overload protection 3P/4P

YEM1E 32A-800A moulded case circuit breaker time delay function MCCB transient voltage overload protection 3P/4P

YEM1L 100A-630A moulded case earth leakage circuit breaker residual current device ground fault circuit breaker 3P/4P

YEM1L 100A-630A moulded case earth leakage circuit breaker residual current device ground fault circuit breaker 3P/4P

Q1 Series CB class 6A-63A ATSE automatic transfer switch 4p MCB type ATS switch

Q1 Series CB class 6A-63A ATSE automatic transfer switch 4p MCB type ATS switch

YUB1 series 3A-63A miniature circuit breaker distribution protection MCB 1P/2P/3P/4P

YUB1 series 3A-63A miniature circuit breaker distribution protection MCB 1P/2P/3P/4P

JXF-800A power Cbinet

JXF-800A power Cbinet

GN series 16A-630A integral type three working positions ATSE intelligent three-phase sampling function china automatic changeover switch with 2p/3p/4p

GN series 16A-630A integral type three working positions ATSE intelligent three-phase sampling function china automatic changeover switch with 2p/3p/4p

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours