YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P

Request a Quote
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P
  • YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P

PRODUCTS DETAILS

Product Details

It is used to transfer infrequently and infrequent motor start(lnm≤400A). Circuit breaker with over-load, short circuit and under-voltage protection function so that protects the circuit and power supply device from being damaged. This circuit breaker has the features of small volume,high breaking capacity,short arc and anti-vibration.

 

Rated current: 63A, 100A, 225A, 400A, 630A, 800A, 1250A

 

Pole: 3P,4P

Product Summary

 

YEM1 series moulded case circuit breaker(hereinafter referred to circuit breaker) is applied in the circuit of AC 50/60HZ,its rated isolation voltage is 800V,rated working voltage is 400V, its rated working current reaches to 800A. It is used to transfer infrequently and infrequent motor start(lnm≤400A). Circuit breaker with over-load, short circuit and under-voltage protection function so that protects the circuit and power supply device from being damaged. This circuit breaker has the features of small volume,high breaking capacity,short arc and anti-vibration.

 

Circuit breaker can be installed in a vertical way.

 

Circuit breaker has isolation function.

Product Parameters

Operating Conditions

 

1.Altitude:≤2000m.

2.Environment temperature:-5℃~+40℃.

3.Tolerance to the influence of moist air.

4.Withstand the effects of smoke and oil mist.

5.Pollution degree 3.

6.Maximum inclination is 22.5℃.

7.In medium without explosion danger,and the medium is not enough to corrode.

8.Metals and places that destroy insulating gases and conductive dust.

9.In the absence of rain and snow.

10Installation category Ⅲ.

Product Choice

Name Details
Product category Moulded case circuit breaker
Design code 1
Current rank (Amp) 63A,100A,225A,400A,630A,800A,1250A
Breaking capacity L,M,H
Pole 3P,4P
Part no. 300 no part(please see the release part no.table)
Rated current 16A~1250A
Use no. None=power distribution type breaker 2=protect motor
Operation type None=handle direct operation,P=Electric operation,Z=Rotating handle operation
N pole shape Four poles products’ N polar form:A type:N polar do not install over-current release,and N polar electrifies all the time,at the same time,N polar does not open and close together with other three poles.B type:N polar do not install over-current release,and N polar opens and closes together with other three poles.C type:N polar installs over-current release,and N polar opens and closes together with other three poles.D type:N polar installs over-current release,and N polar electrifies all the time,at the same time,N polar does not open and close together with other three poles.
Writing None=front board connection,R=behind board connection,PR=Plug-in connection

Precautions

Hot Products

YE41F-1Z-024 Solid State Slim Line Relay

YE41F-1Z-024 Solid State Slim Line Relay

YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P

YEM1 Series 63A-1250A moulded case circuit breaker motor protection MCCB 3P/4P

GN series 16A-630A integral type three working positions ATSE intelligent three-phase sampling function china automatic changeover switch with 2p/3p/4p

GN series 16A-630A integral type three working positions ATSE intelligent three-phase sampling function china automatic changeover switch with 2p/3p/4p

YEM1L 100A-630A moulded case earth leakage circuit breaker residual current device ground fault circuit breaker 3P/4P

YEM1L 100A-630A moulded case earth leakage circuit breaker residual current device ground fault circuit breaker 3P/4P

N series 16A-630A split type two working positions ATSE terminal blocks wiring automatic switches with 2p/3p/4p

N series 16A-630A split type two working positions ATSE terminal blocks wiring automatic switches with 2p/3p/4p

YGL/YGLR series 63A-3150A load isolation switch  changeover switch disconnector fuse combination 3p/4p

YGL/YGLR series 63A-3150A load isolation switch changeover switch disconnector fuse combination 3p/4p

PC/CB Grade ATS Controller

PC/CB Grade ATS Controller

C series 16A-630A split type two working positions ATSE aviation plug wiring automatic transfer switches with 2p/3p/4p

C series 16A-630A split type two working positions ATSE aviation plug wiring automatic transfer switches with 2p/3p/4p

JXF-400A power Cbinet

JXF-400A power Cbinet

Q3 Series CB class 16A-630A ATSE automatic transfer switch 4p MCCB type ATS switch

Q3 Series CB class 16A-630A ATSE automatic transfer switch 4p MCCB type ATS switch

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours